Rates of reaction - kinetics (A2)
Read our general notes on Risk Assessment
I'm investigating the rate of reaction between peroxydisulphate(VI) ions and iodide ions. However, I am a little confused with regards to the method of monitoring the rate of reaction using colorimetry.
210208
Ulex writes
The most direct way of doing this is to prepare a series of solutions of iodine (in KI) with known concentrations covering the expected range of concentrations produced by the reaction. Measure the absorbance of each solution, using an appropriate filter or wavelength setting, and plot a graph of absorbance against concentration. This is your calibration curve.
Now do the reaction in the colorimeter, taking readings of absorbance at measured time intervals. Use the calibration curve to convert these readings into concentrations.
That’s the basic procedure; let us know (via Re:act not by answering this email) if there is still a snag!
Risk assessment
Before attempting any practical work based on the advice and suggestions on this website, you must do the following. Identify any hazards, assess the risks from these hazards, and then decide appropriate control measures to reduce the risks. You must have these approved by those in authority in your school or college laboratory. Do not rely on what is said on this website.
For further guidance see our tutorial on Risk Assessment.
back to Rates of reaction - kinetics (A2)
Rate this page or react
Share your views on this page, 0 ratings so far
updated: 21 February 2008